1 7080-132B March 14, 2014
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
MT. VERNON PELLET STOVE E2
Model(s):
MTV-E2-CSB
MTV-E2-MBK
MTV-E2-PFT
MTV-E2-PDB
MTV-E2-PBK
MTV-E2-PMH
Please read this entire manual before installation and use of this
pellet fuel-burning room heater. Failure to follow these instructions
could result in property damage, bodily injury or even death
061-S-83-2
NOTICE: DO NOT DISCARD THIS MANUAL
Owners Manual
Operation & Care
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
replace.
• Alert children and adults to hazards of high temperatures
• High temperatures may ignite clothing or other
ammablematerials.
• Keep clothing, furniture, draperies and other ammable
materials away.
WARNING
Please read this entire manual
before use of this pellet fuel-burning
room heater. Failure to follow these
instructions could result in property
damage, bodily injury, or death.
• Donotstoreorusegasolineorotheram-
mable vapors and liquids in the vicinity of
this or any other appliance.
• DoNOTburngarbageorammableuids
such as gasoline, naphtha, or engine oil in
room heater.
• Donotoverre-Ifheaterorchimneycon-
nectorglows,youareoverring.Overring
will void your warranty.
• Complywithallminimumclearancesto
combustiblesasspecied.Failureto
complymaycausehousere.
CAUTION
Testedandapprovedforwoodpelletsonly
WARNING
NOTE
ToobtainaFrenchtranslationofthismanual,pleasecontact
yourdealerorvisitwww.quadrare.com
Pour obtenir une traduction française de ce manuel, s’il vous
plaîtcontactervotrerevendeurouvisitezwww.quadrare.com
CAUTION
Check building codes prior to installation.
• InstallationMUSTcomplywithlocal,regional,stateandna-
tional codes and regulations.
• Consultlocalbuilding,reofcialsorauthoritieshavingjuris-
diction about restrictions, installation inspection, and permits.
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

1 7080-132B March 14, 2014O-T LTested and Listed byPortlandOregon USAOMNI-Test Laboratories, Inc.CUSMT. VERN

Seite 2 - ATTENTION

10 7080-132B March 14, 2014MT. VERNON E2K. Fire Characteristics Theoverallheightoftheamewillvarythr

Seite 3

March 14, 2014 7080-132B 11MT. VERNON E2LED Color No. of Flashes between pauses Description Notes Green

Seite 4 - C. Warranty Policy

12 7080-132B March 14, 2014MT. VERNON E2N. Restarting the ApplianceRestart Process 1. When the unit has run

Seite 5

March 14, 2014 7080-132B 13MT. VERNON E2Remote Thermostat: Fahrenheit / Celsius1. Temperatureswillshow

Seite 6 - Run Set UpPrime

14 7080-132B March 14, 2014MT. VERNON E2S. Frequently Asked QuestionsWhat causes my glass to become dirty?

Seite 7 - 1 Listing and Code Approvals

March 14, 2014 7080-132B 15MT. VERNON E23 Maintenance and ServiceB. Quick Reference Maintenance ChartNOT

Seite 8 - 2 Operating Instructions

16 7080-132B March 14, 2014MT. VERNON E2Figure 16.1 - Firepot with large clinkerClinkerFigure 16.2C. Genera

Seite 9

March 14, 2014 7080-132B 17MT. VERNON E2Figure 17.2 - Example of a dirty heat exchangerFigure 17.3Shop Va

Seite 10 - K. Fire Characteristics

18 7080-132B March 14, 2014MT. VERNON E2Figure 18.1 Ash Dump LeverHandle glass assembly with care.When clean

Seite 11

March 14, 2014 7080-132B 19MT. VERNON E2Figure 19.1NOTE• This unit is required to be cleaned frequentl

Seite 12 - Q. Remote Thermostat

2 7080-132B March 14, 2014MT. VERNON E2B. Sample of Serial Number / Safety LabelLOCATION:BackofStoveSeri

Seite 13

20 7080-132B March 14, 2014MT. VERNON E2BaffleLatchesInsert flat head screw driver into “V” section and push

Seite 14

March 14, 2014 7080-132B 21MT. VERNON E2Figure 21.1H. Convection Blower Replacement 1. Follow the prope

Seite 15 - 3 Maintenance and Service

22 7080-132B March 14, 2014MT. VERNON E2I . Combustion/Exhaust Blower Replacement1. Follow the proper shut

Seite 16

March 14, 2014 7080-132B 23MT. VERNON E2With proper installation, operation, and maintenance your applian

Seite 17

24 7080-132B March 14, 2014MT. VERNON E2Symptom Possible Cause Corrective ActionAppliance starts and stops f

Seite 18 - Ash Dump Lever

March 14, 2014 7080-132B 25MT. VERNON E2Symptom Possible Cause Corrective ActionLarge,lazyame(orange

Seite 19

26 7080-132B March 14, 2014MT. VERNON E2Following correction of any Alarm, turn the dial control to the OFF

Seite 20 - Ash Build-Up in Firebox

March 14, 2014 7080-132B 27MT. VERNON E2EXHAUSTTEMPERATURESERIAL PORT(SERVICE ONLY)POT SET TEMP VCCPOT SE

Seite 21

28 7080-132B March 14, 2014MT. VERNON E2Service PartsRMT VERNON E2Beginning Manufacturing Date: Dec 2013 End

Seite 22

March 14, 2014 7080-132B 29MT. VERNON E2Service PartsRMT VERNON E2Beginning Manufacturing Date: Dec 2013

Seite 23 - 4 Troubleshooting Guide

March 14, 2014 7080-132B 3MT. VERNON E2TABLE OF CONTENTS Safety Alert Key:• DANGER! Indicates a haza

Seite 24

30 7080-132B March 14, 2014MT. VERNON E2Service PartsRMT VERNON E2Beginning Manufacturing Date: Dec 2013 End

Seite 25

March 14, 2014 7080-132B 31MT. VERNON E2Service PartsRMT VERNON E2Beginning Manufacturing Date: Dec 2013

Seite 26

32 7080-132B March 14, 2014MT. VERNON E2Service PartsRMT VERNON E2Beginning Manufacturing Date: Dec 2013 End

Seite 27 - 5 Reference Materials

March 14, 2014 7080-132B 33MT. VERNON E2Service PartsRMT VERNON E2Beginning Manufacturing Date: Dec 2013

Seite 28 - MT VERNON E2

34 7080-132B March 14, 2014MT. VERNON E2

Seite 29

March 14, 2014 7080-132B 35MT. VERNON E2

Seite 30

36 7080-132B March 14, 2014DO NOT DISCARD THIS MANUALCAUTION• Importantoperatingandmaintenance instruc-

Seite 31

4 7080-132B March 14, 2014MT. VERNON E2Page 547022-122January 19, 2011R Castile Pellet Insert4021-645C 12-2

Seite 32

March 14, 2014 7080-132B 5MT. VERNON E2R January 19, 20117022-122Page 55Castile Pellet Insert4021-645C 1

Seite 33

6 7080-132B March 14, 2014MT. VERNON E2D. Quick Start GuideNovember 21, 2013QUICK START GUIDE*Before you plu

Seite 34

March 14, 2014 7080-132B 7MT. VERNON E2*BTUwillvary,dependingonthetypeoffuelyouuseinyourappl

Seite 35

8 7080-132B March 14, 2014MT. VERNON E2User Guide2 Operating InstructionsA. Fire SafetyTo provide reasonab

Seite 36 - CONTACT INFORMATION

March 14, 2014 7080-132B 9MT. VERNON E2Figure 9.1 HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FUR

Kommentare zu diesen Handbüchern