Quadra-Fire QFI35FB-C Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Kamine Quadra-Fire QFI35FB-C herunter. Quadra-Fire QFI35FB-C Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Models:
QFI30FB-C
QFI35FB-C
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
NOTICE
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
R
• Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.
A CO detector shall be installed in the room where the
appliance in installed.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer’s
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certi ed kit is used.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

1Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Models:QFI30FB-CQFI35FB-COwner’s ManualInstallation and OperationDO NOT DISCARD

Seite 2 - NATURAL GAS

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 10I. Before Lighting FireplaceBefore operating this fi replace for the fi rst time

Seite 3 - User Guide

11Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 J. Lighting Instructions (IPI)FOR YOUR SAFETY READ BEFORE LIGHTINGTO TURN OFF

Seite 4 - WARRANTY PERIOD:

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 12Initial Break-in Procedure• The appliance should be run three to four hours cont

Seite 5 - WARRANTY EXCLUSIONS:

13Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protective glove

Seite 6 - Listing and Code Approvals

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 14VentingFrequency: SeasonallyBy: HomeownerTools needed: Protective gloves and s

Seite 7

15Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Figure 3.2 IPI Pilot Flame Patterns Burner Ignition and OperationFrequency: An

Seite 8 - Figure 2.2 Clear Space

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 16A. Typical Appliance SystemNOTICE: Illustrations and photos refl ect typical ins

Seite 9 - Figure 2.6 Control Module

17Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 B. Design and Installation ConsiderationsQuadra-Fire gas inserts are designed

Seite 10 - MODULE RESET SWITCH

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 185 5 Fireplace Size Requirements A. Minimum Fireplace OpeningMinimum fi replac

Seite 11 - CAUTION:

19Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Figure 5.2 Fireplace OpeningIn addition to these dimensions, also reference Cl

Seite 12 - L. Frequently Asked Questions

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 2Listing Label Information/LocationModel Name: ___________________________________

Seite 13 - Maintenance and Service

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 20B. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum cl

Seite 14

21Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 A. Vent Termination Minimum ClearancesRoof Pitch H (Min.) Ft.Flat to 6/12...

Seite 15 - Burner Ignition and Operation

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 227 7 Installation Preparation Prepare the existing solid fuel masonry or factor

Seite 16 - Installer Guide

23Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 B. Venting ComponentsCAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protec

Seite 17 - C. Tools and Supplies Needed

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 24C. Connecting Vent PipeReference instructions in the termination kit.• Install

Seite 18 - A. Minimum Fireplace Opening

25Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround

Seite 19 - Figure 5.2 Fireplace Opening

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 26E. Installing Adaptor and Termination CapCAUTION! Risk of Cuts/Abrasions/Flying

Seite 20 - Figure 5.3 Mantel Clearance

27Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 A. Fuel Conversion• Make sure the appliance is compatible with available gas t

Seite 21 - Termination Locations

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 28A. Wiring RequirementsNOTICE: This appliance must be electrically wired and gro

Seite 22 - Installation Preparation

29Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 C. IPI Battery Tray/Battery Installation The IntelliFireTM Plus system has a b

Seite 23 - A. Vent Limits

3Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avo

Seite 24 - ADHESIVE

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 30A. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum cl

Seite 25 - Appliance

31Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 A. Remove Glass AssemblySee Section 12.I.B. Remove the Shipping MaterialsRemov

Seite 26 - WOODBURNING PIPE

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 32G. Ember PlacementWARNING! Risk of Explosion! Follow ember placement instructio

Seite 27 - Gas Information

33Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 H. Install the Log AssemblyLog Set Assembly: LOGS-QFI30FBModels: QFI30FB, QFI3

Seite 28 - Electrical Information

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 34Log #4 (SRV2221-706): Position Log #4 as shown in Figure 9. See Figure 2 and F

Seite 29 - D. Control Module Operation

35Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 2221-935C66Log #6 (SRV2221-705): Position Log #6 as shown in Figure 12. See F

Seite 30 - C. Inspect Firebox

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 36H. Install the Log AssemblyLog Set Assembly: LOGS-QFI35FBModels: QFI35FB, QFI35

Seite 31 - Appliance Setup

37Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Log #4 (SRV2223-706): Position Log #4 as shown in Figure 9. See Figure 2 and

Seite 32 - G. Ember Placement

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 382223-935CFigure 12. Place Log #7Log #7 (SRV2221-707): Position Log #7 as shown

Seite 33 - H. Install the Log Assembly

39Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 J. Air Shutter SettingAir shutter settings should be adjusted by a qualifi ed s

Seite 34 - BASE TINE

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 4B. Limited Lifetime WarrantyX Molded refractory panels4021-645G 2/15 Page 1 o

Seite 35 - Figure 13. Place Log #7

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 4013 13 Troubleshooting With proper installation, operation, and maintenance your

Seite 36

41Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Troubleshooting (continued)Symptom Possible Cause Corrective Action4. Pilot lig

Seite 37

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 4214 14 Reference Materials A. Appliance/Decorative Front Dimension DiagramsDim

Seite 38 - Figure 12. Place Log #7

43Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 FS-QFI30FB, FS-QFI35FB DECORATIVE FRONTSFSL-QFI30FB, FSL-QFI35FB DECORATIVE FRO

Seite 39 - I. Fixed Glass Assembly

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 44TP-QFI30FB, TPQFI35FB DECORATIVE FRONTSTB-QFI30FB/TB-QFI35FB DECORATIVE FRONTSAB

Seite 40 - Troubleshooting

45Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Figure 14.4 Direct Vent Flex Liner KitsFigure 14.5 Direct Vent Flex Liner Acc

Seite 41 - Troubleshooting (continued)

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 46Service PartsRBeginning Manufacturing Date: Aug 2011 Ending Manufacturing Date:

Seite 42 - Figure 5.2

47Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Service PartsRBeginning Manufacturing Date: Aug 2011 Ending Manufacturing Date:

Seite 43

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 48Service PartsRBeginning Manufacturing Date: Aug 2011 Ending Manufacturing Date:

Seite 44

49Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 Service PartsRBeginning Manufacturing Date: Aug 2011 Ending Manufacturing Date:

Seite 45 - B. Vent Kits Components

5Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 B. Limited Lifetime Warranty (continued)WARRANTY CONDITIONS:• This warranty on

Seite 46 - QFI30FB-C

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 50Quadra-Fire, a brand of Hearth & Home Technologies 7571 215th Street West, L

Seite 47 - QFI35FB-C

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 6C. BTU Specifi cationsMODELS: QFI30FB-C, QFI35FB-CLABORATORY: Underwriters Labora

Seite 48 - QFI30FB-C, QFI35FB-C

7Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 2 2 Operating Instructions Figure 2.1 General Operating PartsB. Your Fireplac

Seite 49

Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 8C. Clear SpaceWARNING! DO NOT place combustible objects in front of the fi replace

Seite 50 - DO NOT DISCARD THIS MANUAL

9Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15 G. IPI Battery Tray/Battery Installation The IntelliFireTM Plus system has a b

Kommentare zu diesen Handbüchern

Keine Kommentare