Quadra-Fire QV36DB-A Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Kamine Quadra-Fire QV36DB-A herunter. Quadra-Fire QV36DB-A Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Model:
QV36DB
Installers Guide
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Printed in U.S.A. Copyright 2005
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. And foreign patents pending.
Please contact your Quadra-Fire dealer with any
questions or concerns. For the number of your nearest
dealer, please call 1-800-926-4356
Quadra-Fire, a brand of Hearth & Home Technologies Inc.
1445 North Highway, Colville, WA 99114
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Installers Guide

1Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05- Do not store or use gasoline or other flam-mable vapors and liquids in the vicinity of thisor

Seite 2

13Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 5. Vent System Components and Termination KitsStep 3. Installing the Vent SystemA. Vent

Seite 3

14 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05 Figure 6. Straight Up Vertical VentingSTRAIGHT UPVERTICAL VENTINGV (FT.)40' MAX. (12

Seite 4 - Approvals and

15Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05HORIZONTAL VENTINGKit No. H Max. RunDVP-TRAP 24" (610 mm)Figure 10. Corner InstallationNOTE

Seite 5 - Getting Started

16 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 12.Venting with One 90° ElbowNOTE: If a 90o elbow is first attached to the unit,the max

Seite 6

17Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05VENTING WITH TWO (2) 90o ELBOWS V FT. H + H1 (FT.)1' MIN. (305mm)

Seite 7 - Installing the Fireplace

18 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 15. Venting with three 90° elbowsVENTING WITH THREE (3) 90° ELBOWS1´MIN. (305mm) 2´MAX

Seite 8

19Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.)1' MIN. (305mm) 5' MAX. (1.52m)2

Seite 9 - AT EACH JOINT

20 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 17B. Installing Vent ComponentsAfter determining which set of starting collars will be

Seite 10 - Identifying Vent Components

21Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 19• Continue adding vent components, locking each succeed-ing component into place.• Ensu

Seite 11 - Flue Restrictor Instructions

22 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/055. Install FirestopsFor Horizontal Runs - Firestops are REQUIRED on bothsides of a combustible

Seite 12 - - CHART

2 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05These units MUST use one of the vent systemsdescribed in the Installing the Fireplace section of

Seite 13

23Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 25. Ceiling Firestop (Ceiling Side)If the area above the ceiling IS an attic, position a

Seite 14

24 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05V= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTED Figure 28. Vent

Seite 15 - V H H + H

25Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05For Vertical Terminations - To locate the vent and installthe vent sections:• Locate and mark th

Seite 16 - NOTE: V+V

26 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Step 4. Positioning, Leveling, and Securing the Fireplace• Place the fireplace i

Seite 17 - DVP PIPE:

27Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05• Insert insulation from the outside of the fireplace andpack the insulation tightly to totally

Seite 18

28 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Step 8. Wiring the FireplaceNOTE: Electrical wiring must be installed by a licensedelectrician

Seite 19 - 12"

29Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Step 9. FinishingFigure 35 shows the minimum vertical and correspondingmaximum horizontal dimen

Seite 20 - C. Vent Termination

30 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Installing the TrimCombustible materials may be brought up to the specifiedclearances on the si

Seite 21 - (See Note 5)

31Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Step 12. Lighting the ApplianceSTANDING PILOT IGNITIONA. This appliance (standing pilot versio

Seite 22

32 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/054Maintaining and Servicing Your FireplaceFireplace MaintenanceAlthough the frequency of your fi

Seite 23

3Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05TABLE OF CONTENTSSafety and Warning Information ...

Seite 24 - Step 6. The Gas Supply Line

33Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05TroubleshootingWith proper installation, operation, and maintenance your gas fireplace willprovi

Seite 25

34 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Symptom Possible Cause Corrective Action3. (Continued) f. High limit switch is defective orhas

Seite 26 - TOP & SIDE SEAL JOINT

35Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Lifetime WarrantyLIMITED LIFETIME WARRANTYThe Hearth & Home Technologies limited Lifetime Wa

Seite 27 - ASSEMBLY

7Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Appliance CertificationThe fireplace model discussed in this Installers Guide hasbeen tested to

Seite 28

8 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Introducing the Quadra-Fire Gas FireplaceQuadra-Fire direct vent gas fireplaces are designed to

Seite 29 - After the Installation

9Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Figure 1. Diagram of the QV36DB41 1/8[1044mm]38[965mm]36 1/8[916mm]25 1/4[642mm]34 5/8[879mm]8 5/

Seite 30 - Troubleshooting

10 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/053Installing the FireplaceStep 1. Locating the FireplaceFor space and clearance requiremen

Seite 31 - Troubleshooting (continued)

11Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05Framing should beconstructed of 2 X 4lumber or heavier.A. ... 42”*B. ...38 1/2”C

Seite 32 - Lifetime Warrant

12 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05NOTE: PIPES OVERLAP 1-1/4 INCHESAT EACH JOINT.Figure 4.DVP-Series Direct Vent Component Specif