Quadra-Fire TOPAZ Direct Vent Room Heater TOPAZ-D-CWL Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Kamine Quadra-Fire TOPAZ Direct Vent Room Heater TOPAZ-D-CWL herunter. Quadra-Fire TOPAZ Direct Vent Room Heater TOPAZ-D-CWL Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
www.quadrafire.com
September 1, 2008
7009-113G
Quartet Front
Solitaire Front
TOPAZ
DIRECT VENT ROOM HEATER
Owners Manual
Installation and Operation
Model:
839-1290
839-1320
839-1340
844-4120
TOPAZ-D-CSB
TOPAZ-D-CWL
R
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
DO NOT DISCARD THIS MANUAL
CAUTION
• Important operating and
maintenance instructions
included.
Leave this manual with
party responsible for use
and operation.
• Read, understand and
follow these instructions
for safe installation and
operation.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
What to do if you smell gas
- Do not try to light any appliance.
Do not touch any electrical switch. Do not use any
phone in your building.
- Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
This appliance may be installed as an OEM installation in manufactured
home (USA only) or mobile home and must be installed in accordance with
the manufacturer's instructions and the manufactured home construction
and safety standard, Title 24 CFR, Part 3280 or Standard for Installation
in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated on the
rating plate.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised by an NFI
certified professional.
DO NOT
DISCARD
In the Commonwealth of Massachusetts:
installation must be performed by a licensed plumber or gas
fitter.
See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND cool
down.
Hot glass will cause burns.
Do not touch glass until it is
cooled
WARNING
• NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in the same
room as appliance
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
combustibles away.
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

www.quadrafire.com September 1, 2008 7009-113GQuartet FrontSolitaire FrontTOPAZDIRECT VENT ROOM HEATER Owner’s ManualInstallation and OperationMod

Seite 2 - Test Lab & Report No

Page 10September 1, 2008Quadra-Fire · Topaz · 7009-113G5Vent InformationA. Venting ComponentsB. Use of ElbowsIn order to comply with applicable codes

Seite 3 - - TABLE OF CONTENTS

September 1, 2008Page 11Quadra-Fire · Topaz · 7009-113GD. How to Use the Vent Graph E. Venting Guidelines1. Measure the vertical distance from the c

Seite 4 - Topaz (LP)

Page 12September 1, 2008Quadra-Fire · Topaz · 7009-113GFemale Locking LugsMale Locking LugsStep 1. Determine the desired location of the appliance. C

Seite 5 - Massachusetts

September 1, 2008Page 13Quadra-Fire · Topaz · 7009-113GFigure 5.5When installing in a rear vent configuration with no vertical rise: a Snorkel Kit mu

Seite 6 - Getting Started

Page 14September 1, 2008Quadra-Fire · Topaz · 7009-113GStep 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent

Seite 7 - Millimeters

September 1, 2008Page 15Quadra-Fire · Topaz · 7009-113GStep 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) t

Seite 8 - Termination Locations

Page 16September 1, 2008Quadra-Fire · Topaz · 7009-113GStep 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance

Seite 9

September 1, 2008Page 17Quadra-Fire · Topaz · 7009-113GCeiling FirestopNailsMinimum 1 in. (24mm) ClearanceMinimum 1 in. (24mm) ClearanceMinimum 1 in.

Seite 10 - Horizontal

Page 18September 1, 2008Quadra-Fire · Topaz · 7009-113G2. Cathedral CeilingLevelCathedral Ceiling Support Box2 in. (51mm) Min. belowfinished ceilingC

Seite 11 - Figure 5.2

September 1, 2008Page 19Quadra-Fire · Topaz · 7009-113G3. Class A Metal ChimneyFigure 5.20 High Wind Termination CapSheet Metal ScrewsDrill Four 1/8

Seite 12 - Figure 5.3

Page 2Quadra-Fire · Topaz · 7009-113G September 1, 2008and Welcome to the Quadra-Fire Family!Hearth & Home Technologies welcomes you to our tra

Seite 13 - Top Vent

Page 20September 1, 2008Quadra-Fire · Topaz · 7009-113G4. Existing Masonry ChimneyType A - Up & Out Installations for Top Vent Configuratio

Seite 14 - Figure 5.7

September 1, 2008Page 21Quadra-Fire · Topaz · 7009-113G10 in. x 10 in. (254mm x 254mm) framed opening in wallStudwallMasonry ChimneyRetro Connector(4

Seite 15 - Figure 5.12

Page 22September 1, 2008Quadra-Fire · Topaz · 7009-113GHigh Wind Termination CapTop Adaptor(3) Sheet Metal ScrewsFlashingStep 9.Attach the flex to th

Seite 16 - Figure 5.15

September 1, 2008Page 23Quadra-Fire · Topaz · 7009-113G6Gas InformationA. Fuel ConversionsBefore making gas connections ensure that the appliance be

Seite 17 - Figure 5.16

Page 24September 1, 2008Quadra-Fire · Topaz · 7009-113GA B C Mounting ScrewsPressure Regulator TowerDiaphragmFigure 6.8 Turn control knob to the OF

Seite 18 - Figure 5.19

September 1, 2008Page 25Quadra-Fire · Topaz · 7009-113GFire Risk.Explosion Risk.• If the information in these instructions is not followed exactly,

Seite 19 - Figure 5.21

Page 26September 1, 2008Quadra-Fire · Topaz · 7009-113G• A small amount of air will be in the gas supply lines. When first lighting appliance it will

Seite 20 - Figure 5.24

September 1, 2008Page 27Quadra-Fire · Topaz · 7009-113G7Electrical InformationA. Recommendation for WireC. Standing Pilot Ignition System WiringSee

Seite 21 - Figure 5.26

Page 28September 1, 2008Quadra-Fire · Topaz · 7009-113GFigure 7.1CAUTIONLabel all wires prior to disconnection when servicing controls. Wiring errors

Seite 22 - Figure 5.30

September 1, 2008Page 29Quadra-Fire · Topaz · 7009-113G8Appliance SetupA. Remove Shipping MaterialsRemove shipping materials from inside or undernea

Seite 23 - Gas Information

Page 3Quadra-Fire · Topaz · 7009-113G - TABLE OF CONTENTS - September 1, 2008Section 1: Listing and Code Approvals A. Appliance Certification

Seite 24 - Diaphragm

Page 30September 1, 2008Quadra-Fire · Topaz · 7009-113GD. AccessoriesInstall approved accessories per instructions included with accessories. Refer

Seite 25 - B. Gas Pressures

September 1, 2008Page 31Quadra-Fire · Topaz · 7009-113GE. Front InstallationFronts shipped attached to faceFigure 8.12 To remove the face, loosen

Seite 26 - C. Gas Connection

Page 32September 1, 2008Quadra-Fire · Topaz · 7009-113GNOTE: Side brick panels will fit only if installed at an angle. Do not attempt to push the bri

Seite 27 - Electrical Information

September 1, 2008Page 33Quadra-Fire · Topaz · 7009-113GFigure 8.20 Insert locator pin into right front log. Insert rear log onto log pan over stud

Seite 28 - Thermocouple

Page 34September 1, 2008Quadra-Fire · Topaz · 7009-113GNOTE: This blower utilizes a snap disc to control ON and OFF operation. When the correct tempe

Seite 29 - Appliance Setup

September 1, 2008Page 35Quadra-Fire · Topaz · 7009-113GFigure 8.31 Blower Wiring DiagramFan Speed ControlThermal Disc(110 VAC)Power CordBLACK

Seite 30

Page 36September 1, 2008Quadra-Fire · Topaz · 7009-113GSee Vent Graph for Recommendations on page 11 before you begin your adjustment. If your insta

Seite 31 - Quartet Front

September 1, 2008Page 37Quadra-Fire · Topaz · 7009-113G9Operating InstructionsA. Before Lighting ApplianceRead this entire manual prior to using the

Seite 32 - G. Positioning the Logs

Page 38September 1, 2008Quadra-Fire · Topaz · 7009-113GC. Lighting Appliance1. Set the thermostat to lowest setting. 2. Turn off all electric powe

Seite 33

September 1, 2008Page 39Quadra-Fire · Topaz · 7009-113GD. After Appliance is LitWhen you light your appliance, you may notice that it pro-duces heat

Seite 34 - 5/16" nut

Page 4September 1, 2008Quadra-Fire · Topaz · 7009-113G1Listing and Code ApprovalsThe product is listed to ANSI standards for “Vented Gas Appliance He

Seite 35 - September 1, 2008

Page 40September 1, 2008Quadra-Fire · Topaz · 7009-113G10TroubleshootingWith proper installation, operation, and maintenance your gas appliance will

Seite 36 - REAR VENT INSTALLATIONS:

September 1, 2008Page 41Quadra-Fire · Topaz · 7009-113GSymptom Possible Cause Corrective Action3. (Continued) c. Defective valve. Turn the valve kn

Seite 37 - Operating Instructions

Page 42September 1, 2008Quadra-Fire · Topaz · 7009-113G11Maintaining and Servicing Your ApplianceAlthough the frequency of your appliance servicing a

Seite 38 - TO TURN OFF GAS TO APPLIANCE

September 1, 2008Page 43Quadra-Fire · Topaz · 7009-113GInspect Maintenance TasksDoors 1. Inspect for scratches, dents or other damage and repair as

Seite 39 - ISSUE SOLUTIONS

Page 44September 1, 2008Quadra-Fire · Topaz · 7009-113G12Reference MaterialsA. Appliance Dimension DiagramDimensions are actual appliance dimensions.

Seite 40 - Troubleshooting

September 1, 2008Page 45Quadra-Fire · Topaz · 7009-113GB. Vent Components DiagramFigure 12.2 SL-D Series Vent Components4 in. (102 mm) inner pipe

Seite 41

Page 46September 1, 2008Quadra-Fire · Topaz · 7009-113GC. Vent Components List DescriptionHHT SL-P M= Multi Pack (6)Simpson Dura-VentDirectVent Pro S

Seite 42

September 1, 2008Page 47Quadra-Fire · Topaz · 7009-113G45° Elbow, Swivel, Black - 46DVA-E45B - - SV4EB4590° Elbow, Galvanized SLP90M See Swivel 4DT-E

Seite 43 - A. Maintenance Tasks

Page 48September 1, 2008Quadra-Fire · Topaz · 7009-113GD. Service Parts ListR TOPAZ(NG, LP) Exploded Parts DiagramBeginning Ma

Seite 44 - Reference Materials

September 1, 2008Page 49Quadra-Fire · Topaz · 7009-113GIMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer&

Seite 45 - B. Vent Components Diagram

September 1, 2008Page 5Quadra-Fire · Topaz · 7009-113GNOTE: The following requirements reference various Massachusetts and national codes not contain

Seite 46 - C. Vent Components List

Page 50September 1, 2008Quadra-Fire · Topaz · 7009-113GIMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer&

Seite 47 - - 46DVA-ES 4DT-OS - SV4SU

September 1, 2008Page 51Quadra-Fire · Topaz · 7009-113GOrifice, Pilot, NG, EZ, #62 842-4440Paint, Touch-up, Matte Black 7000-304Paint, Touch-up, Porce

Seite 48 - Service Parts List

Page 52September 1, 2008Quadra-Fire · Topaz · 7009-113GPart DescriptionAlphabetical OrderPart #Blower Assembly with Speed Control (Rheostat) BK-GASDe

Seite 49 - Service Parts List (cont’d.)

September 1, 2008Page 53Quadra-Fire · Topaz · 7009-113GF. Service and Maintenance LogDate of Service Performed By Description of Service

Seite 50

Page 54September 1, 2008Quadra-Fire · Topaz · 7009-113GG. Warranty PolicyHearth & Home Technologies LIMITED WARRANTYHearth & Home Technologi

Seite 51

September 1, 2008Page 55Quadra-Fire · Topaz · 7009-113G HHT’s obligation under this warranty does not extend to damages resulting from: (1) instal

Seite 52 - Accessories

Page 56Quadra-Fire · Topaz · 7009-113G September 1, 2008Hearth & Home Technologies1445 North HighwayColville, WA 99114Division of HHT INDUSTRI

Seite 53

Page 6September 1, 2008Quadra-Fire · Topaz · 7009-113G2Getting StartedCheck building codes prior to installation.• Installation MUST comply with loc

Seite 54 - 4021-645A 09-01-08

September 1, 2008Page 7Quadra-Fire · Topaz · 7009-113G3Appliance Location and ClearancesA. Selecting Appliance LocationNOTE: · Illustrations reflect

Seite 55

Page 8September 1, 2008Quadra-Fire · Topaz · 7009-113G4Termination LocationsA. Vent Termination Minimum ClearancesGasTerminationWood & Fuel OilTe

Seite 56 - Your Records for Model:

September 1, 2008Page 9Quadra-Fire · Topaz · 7009-113GFigure 4.4 V= VENT TERMINALX= AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTEDA = 12 i

Kommentare zu diesen Handbüchern

Keine Kommentare