1Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11
Model:
HUDBAY-INS
DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
NOTICE
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Installation and service of this appliance should be
performed by quali ed personnel. Hearth & Home
Technologies suggests NFI certi ed or factory trained
professionals, or technicians supervised by an NFI
certi ed professional.
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
WARNING
R
• Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.
A CO detector shall be installed in the room where the appliance
in installed.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable
materials.
Keep clothing, furniture, draperies and other ammable
materials away.
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Seitenansicht 0
1 2 3 4 5 6 ... 42 43

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

1Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Model:HUDBAY-INS• DO NOT store or use gasoline or other fl am-mable vapors and liquids in th

Seite 2 - MODEL: XXXXXXX

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1110Initial Break-in Procedure• The appliance should be run three to four hours continuously on h

Seite 3 - User Guide

11Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protective gloves, glass cle

Seite 4 - LIMITED LIFETIME WARRANTY

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1112B. Maintenance Tasks-Service TechnicianThe following tasks must be performed by a qualifi ed

Seite 5 - WARRANTY EXCLUSIONS:

13Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11A. Typical Appliance SystemNOTICE: Illustrations and photos refl ect typical installations

Seite 6 - Listing and Code Approvals

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1114B. Design and Installation ConsiderationsQuadra-Fire gas inserts are designed for installati

Seite 7

15Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/115 5 Fireplace Size Requirements A. Minimum Fireplace OpeningMinimum fi replace opening re

Seite 8 - IGNITER BUTTON

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1116B. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-ances to

Seite 9 - H. Standing Pilot Ignition

17Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11A. Vent Termination Minimum ClearancesRoof Pitch H (Min.) Ft.Flat to 6/12...

Seite 10 - J. Frequently Asked Questions

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11187 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-c

Seite 11 - Maintenance and Service

19Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11B. Venting ComponentsCAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves

Seite 12

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/112Model Name: ___________________________________________ Date purchased/installed: ____________

Seite 13 - Installer Guide

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1120Figure 8.2 CUT AND BEND FLASHING AS NEEDEDTO FIT CHIMNEYSEALANTADHESIVE• Trim chimney top

Seite 14 - C. Tools and Supplies Needed

21Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11F. Installing Adaptor and Termination CapFor installation of termination cap see minimum v

Seite 15 - A. Minimum Fireplace Opening

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1122A. Fuel Conversion• Make sure the appliance is compatible with available gas types.• Convers

Seite 16 - Hudson Bay Insert

23Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Figure 9.5Figure 9.6Figure 9.7Note: Do not remove retaining clip from the pilot hood.Note:

Seite 17 - Termination Locations

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1124E. Gas Connection • Refer to Reference Section 15 for location of gas line access in applian

Seite 18 - Installation Preparation

25Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11NOTICE: DO NOT wire 110 VAC to the millivolt valve! This will damage the valve.ON/OFF Switc

Seite 19 - A. Vent Limits

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1126C. Blower InstallationIncluded in kit: Blower.Tools required: Powered Phillips head screwdri

Seite 20 - E. Remote Control

27Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Figure 10.7 Blower Wiring DiagramF = 1/4 in. (6 mm) female spadeM = 1/4 in. (6 mm) male s

Seite 21 - Wood Burning

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/112811 11 Finishing A. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimu

Seite 22 - Gas Information

29Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11A. Remove Glass AssemblySee Section 12.L.B. Remove the Shipping MaterialsRemove shipping m

Seite 23 - Figure 9.8

3Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avoided will re

Seite 24 - D. Gas Pressure

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1130F. Grille InstallationRemove the door of appliance. Remove the four screws (two at each end)

Seite 25 - Electrical Information

31Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11H. Ember PlacementWARNING! Risk of Explosion! Follow ember placement instructions in manual

Seite 26 - C. Blower Installation

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1132I. Brick InstallationThe pilot shield has to be removed to install or remove the brick refrac

Seite 27 - M = 1/4 in. (6 mm) male spade

33Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Figure 12.16 Note: For the Hudson Bay Insert the lower brick retainer is used.REAR BRICK R

Seite 28 - Finishing

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1134Figure 12.24Figure 12.25Figure 12.26Note: Do not close so much as to cause a sooty fl ame. Imp

Seite 29 - Appliance Setup

35Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11L. Fixed Glass AssemblyRemoving Fixed Glass AssemblyWARNING! Risk of Asphyxiation! Handle

Seite 30 - G. Panel Set Installation

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1136A. Standing Pilot Ignition System13 13 Troubleshooting With proper installation, operation,

Seite 31 - H. Ember Placement

37Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Troubleshooting (continued)Symptom Possible Cause Corrective Action3. (Continued) C. Valve

Seite 32 - I. Brick Installation

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/113814 14 Reference Materials A. Appliance Dimension DiagramDimensions are actual appliance di

Seite 33 - J. Positioning the Logs

39Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11B. Vent Kits ComponentsDirect Vent Flex Liner Kits (see Figure 14.2)LINK-DV30B: Masonry 3

Seite 34 - K. Air Shutter Adjustment

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/114B. Limited Lifetime Warranty4021-645C 12-29-10 Page 1 of 2Hearth & Home Technologies Inc

Seite 35 - L. Fixed Glass Assembly

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1140RC. Service PartsHudson Bay InsertHUDBAY-INSBeginning Manufacturing Date: April 2003Ending Ma

Seite 36 - Troubleshooting

41Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11HUDBAY-INSC. Service Parts List IMPORTANT: THIS IS DATED INFORMATION. When requesting serv

Seite 37 - Troubleshooting (continued)

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/1142RService PartsHUDBAY-INSBeginning Manufacturing Date: April 2003Ending Manufacturing Date: __

Seite 38 - Reference Materials

43Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11Quadra-Fire, a brand of Hearth & Home Technologies Inc. 7571 215th Street West, Lakevil

Seite 39 - B. Vent Kits Components

5Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11B. Limited Lifetime Warranty (continued)4021-645C 12-29-10 Page 2 of 2WARRANTY CONDITIONS:

Seite 40 - HUDBAY-INS

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/116C. BTU Specifi cationsThis product is listed to ANSI standards for “Vented Gas Appliance Heater

Seite 41 - In Depot

7Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/112 2 Operating Instructions Figure 2.1 General Operating PartsB. Your FireplaceWARNING! DO

Seite 42

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/118C. Clear SpaceWARNING! DO NOT place combustible objects in front of the fi replace or block lou

Seite 43 - DO NOT DISCARD THIS MANUAL

9Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11H. Standing Pilot Ignition1. Set the thermostat to lowest setting. 2. Turn off all elect